Specifications
Housing Polycarbonate Aluminum
  UV Stabilized  
     
Body Bronze Monel
    316 SS
     
Bellows Bronze Monel
    316 SS
    Inconel
     
Seals Buna-N Viton
    EPR
    Teflon
     
Crystal Polycarbonate Glass
    Plastic
     
Gear Movement Bronze 316 SS
     
Accuracy ± 3% F.S  
Repeatability ± 1% F.S  
     

Pressure

   

Maximum

180 psig 400 psig

Minimum

  10 psig   10 psig
     
Temperature    

Maximum

212 °F 350 °F

Minimum

 -30 °F  -80 °F
TM
FLO-GAGE
Standard              Options
How to Order

Selecting the Flo-Gage is easy... and our factory staff is always glad to help!

Select a) body size, b) series, c) body material, d) direction of flow, e) full scale flow rate, f) options (if required) and g) switches (if required).

a) BODY SIZE - the pipe size at the meter inlet. See "Standard Flow Rates and Body Sizes" for available sizes.

b) SERIES (end connection)

    7 - Threaded units provided with FNPT connections standard.

         (FBSP parallel threads available on request for Bronze and Monel)

    8 - Wafer units mount between any standard 150 or 300 class flanges

         (or international equivalent).

c) MATERIAL

    1 = Bronze

    2 = Monel

    3 = Stainless Steel (316)

d) FLOW DIRECTION (L, R, VUL, VUR, VDL, VDR)

 

 

 

 

 

 

 

e) FLOW RATE (full scale GPM for liquids and SCFM for compressed gas). Prefix full scale with "M" for metric units. Non-standard flow rates require option "E".

f) OPTIONS (if required) - Select from the Table of Options Below.

g) SWITCHES (if required) - See Options Table Below.

    1S2 - One single pole double throw dry contact form C switch

    2S2 - Two single pole double throw dry contact form C switches

    Example: 3/4-71-R-20-AD-1S2 is the catalog number for a 3/4" FNPT connection Series 7000 Flo-Gage of Bronze construction, flow direction from left to right, flow range of 20 GPM full scale, equipped with optional seals of Viton, optional gasketed case and one single pole double throw reed switch.

    Example    3/4 - 71 - R - 20 - AD - 1S2

                        I     I I     I     I     I        I

                        a    bc    d    e    f        g

Curve A - bronze bellows

 
 
   

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

Specifications (continued)

Description

The RCM Flo-Gage™ is a direct reading flow meter with a large, easy to read dial calibrated in engineering units (GPM, SCFM, I/min, etc.).

The Flo-Gage™ measures flow based on a pressure differential created across a built-in calibrated nozzle. The meter is self-contained and complete. It does not require external power connections, separate orifices, or blocking, purging or equalizing valves.

The Flo-Gage™ is suitable for measuring water, oil and most other low viscosity liquids which do not deposit out and which are compatible with the materials of construction.

The Flo-Gage™ is also suitable for measuring compressed air, oxygen, carbon dioxide and many other nontoxic compressed gases (specify option I). Saturated Steam can also be measured up to 120 psig (Option K).

The Flo-Gage™ can be fitted with a transmitter to provide a current output for remote indication, recording or totalization, or with reed switch contacts for signaling high or low flows.

Features and Benefits

  • Sturdy in-line metal construction to withstand piping stresses without breaking

  • Black on white dial won't crack, glaze or become hard to read

  • Expanded 3.5" (90 mm) 270° analog dial for reading at a glance

  • Suitable for use with both opaque and clear fluids

  • Measures 6:1 range with ± 3% F.S. accuracy

  • Dial and case factory configured for quick installation but easily field re-configured if needed

  • Liquid flow ranges from 4 GPH (15 l/h) in 1/2" meter to 3000 GPM (12000 l/m) in 8" flow meter

  • Gas flow ranges from 40 SCFH (1 Nm³/h) in 1/2" meter to 20,000 SCFM (600 Nm³/m) in 8" flow meter

Applications

The RCM Flo-Gage™ flow meter has been developed for industrial and  commercial applications where durability and reliability are important considerations in the monitoring of flow. The Flo-Gage  has accuracy for most industrial processes and is particularly suited for applications where compactness, low cost, minimal maintenance and resistance to accidental damage are important factors.

Typical applications include: lube oil monitoring, blending processes, cooling water, reverse osmosis systems, and compressed air measurement.

 

TM
FLO-GAGE
Transmitter Option         W, X, Y, Z                W2, W3

                                        (4-wire)                  (2-wire)  

 

Table of Options
Accuracy    
     Horizontal ± 3% F.S. ± 3% F.S.
     Vertical ± 5% F.S. ± 5% F.S.
Minimum Flow Rate 30% F.S. 15% F.S.
Ambient Temp Limit 120 °F, 50 °C 120 °F, 50 °C
Current Output 4-20mA 4-20mA
     Ohms max. 800 650 (RW3 350)
Contact Rating (Hi/Lo) 3.0 amp @ 24V  
  1.0 amp @ 117V  
  0.5 amp @ 230V  
Frequency Output 0-1000 Hz F.S.  
  5V Peak  
  270 ms on time  
Electrical Rating General Purpose  
Power Input 100mA 25mA
Optional - PS-24 24Vdc 24Vdc

 

Reed Switches (Option 1S2 or 2S2)

      TRANSMITTERS
A Viton Seals W 4-20mA DC 4-Wire Transmitter
B EPR Seals W2 4-20mA DC 2-Wire Transmitter
B2 Teflon Seals W3 4-20mA DC 2-Wire Transmitter (Output Only)
C Calibrated for Specific Gravity (customer specified) RW3 Digital Display Readout (Rate and Total)
D Gasketed Case X Hi / Lo Alarm Relays
D2 Gasketed Case with Condulet Y 0 - 1000 Hz Frequency Transmitter
E Non-Standard Flow Rate Z Combination of W, X, Y
ES Low Flow Rate (below 2 GPM)    
F Aluminum Housing with Plastic Dial Crystal   REED SWITCHES
F2 Aluminum Housing with Glass Dial Crystal -1S2 1 Single Pole Double Throw Reed Switch
G Custom Scales and Dials -2S2 2 Single Pole Double Throw Reed Switches
H High Pressure Service (400psig max) -LED Light Emitting Diode  Coming Soon!
I Compressed Gas Service    
J Peak Flow Indicator   APPROVALS
K Saturated Steam Service -EM Electromagnetic Compatibility 89/336/EEC
N Ammonia Service -IS Intrinsic Safety 94/9/EC
P Panel Mount    
R2 Remote Readout, Bronze   ACCESSORIES
R3 Remote Readout, 316 SS DR-1 Remote Digital Display (requires transmitter)
T Expanded Temperature Range (350 °F max) PS-24 Power Supply, 24Vdc Out, 115Vac In, 100mA
V High Viscosity Service (5 - 500 cps - specify) KT-1 Fittings for Connecting Remote Readout, R2, Brass
    KT-3 Fittings for Connecting Remote Readout, R3, SST

Switches are field adjustable from 30% and 90% of full scale or can be factory set to customer requirements.
Setability ± 5% F.S.
Repeatability ± 1% F.S.
Hysteresis 7 to 13% F.S.
Contact Rating 10 watts
Voltage 175Vdc - max
  125Vac - max
Current 350mA max switching
  1.0 amp max carry
   
   
   

 
 
   
Size  

Full Scale Flow Range

 
     Liquid Gas (option I)

Steam

FLO-GAGE

Standard Flow Rates & Body Sizes

Series 7000 (threaded) and 8000 (wafer)

in    mm GPM l/m SCFM Nm³/h #/h
1/4 08 2 8 10 15 40
    3 15 20 30 60
    4 25 30 50 80
             
1/2 15 2 8 10 15 40
    3 10 20 30 60
    4 15 30 50 80
    6 25 40 80 120
    10 40 60 100 200
             
3/4 20 6 25 60 100 120
    10 40 100 150 200
    15 60 150 200 300
    20 80 200 300 400
             
1 25 15 60 150 250 300
    20 80 200 400 400
    30 120 300 500 600
    40 150 400 600 800
             
1 1/2 40 30 120 300 500 600
    40 150 400 600 800
    60 240 600 1000 1000
    100 400 800 1200 2000
             
2 50 40 150 400 600 800
    60 240 600 1000 1000
    100 400 800 1200 2000
    150 600 1000 1500 3000
    200 800 1200 2000 4000
             
3 80 200 800 1000 1500 4000
    300 1000 2000 3000 6000
    400 1500 3000 5000 8000
    500 2000 4000 6000 10000
Optional Low Flow Range (option ES)
Size   Full Scale Flow Range  
  Liquid Gas (option I) Steam
in    mm GPH l/h cc/m SCFH Nm³/h #/h
1/2 15 4 15 200 40 1 2
    6 20 300 60 2 3
    10 40 400 100 3 4
    15 60 600 150 4 6
    20 80 1000 200 6 8
    30 120 2000 300 8 10
    40 150 3000 400 10 15
    60 240 4000      
    100 400 6000      
Series 8000 only (wafer)
Size  

Full Scale Flow Range

 
  Liquid Gas (option I)

Steam

in    mm GPM l/m SCFM Nm³/h #/h
2 1/2 65 60 240 600 1000 1000
    100 400 800 1200 2000
    150 600 1000 1500 3000
    200 800 1200 2000 4000
             
in mm GPM l/m SCFM Nm³/m #/h
4 100 300 1000 1500 50 6000
    400 1500 3000 100 8000
    600 2400 5000 150 10000
    800 3000 6000 200 15000
             
5 125 300 1000 1500 50 6000
    400 1500 3000 100 8000
    600 2400 5000 150 10000
    800 3000 6000 200 15000
             
6 150 600 2400 3000 100 10000
    800 3000 5000 150 15000
    1000 4000 8000 250 20000
    2000 8000 15000 400 40000
             
8 200 600 2400 5000 150 10000
    1000 4000 8000 250 20000
    2000 8000 15000 400 40000
    3000 12000 20000 600 60000
Pressure Drop Characteristics

Curve B - monel, SS, Inconel bellows

Series 7000 Flo-Gage
 
   
in mm in mm in mm
1/4 08 5.95 3.06 n/a n/a
1/2 15 5.95 3.06 6.62 168
3/4 20 5.95 3.06 7.06 179
           
1 25 6.07 154 7.25 184
1 1/2 40 6.39 162 7.81 198
2 50 6.80 172 8.00 203
           
2 1/2 65 n/a n/a 8.54 217
3 80 7.48 190 8.87 225
4 100 n/a n/a 9.95 252
           
5 125 n/a n/a 10.36 263
6 150 n/a n/a 11.05 280
8 200 n/a n/a 12.30 311
Selecting Flow Meters for Liquid Service

The Flo-Gage™ can be used to meter flow rates of a wide variety of liquids including water, fuel oil (#2 through #6), lubricant, solvents and many chemical compounds.

For best accuracy, select a flow rate which will permit normal operation in the upper half of the flow meter scale.

To choose the proper meter, select pipe size and full scale flow rate from the chart of "Standard Flow Rate" and "Body Sizes".

Selecting Flow Meters for Compressed Gas Service

The Flo-gage™ can be used to measure flow rate of various gases such as air, nitrogen, oxygen, carbon dioxide, hydrogen, propane, methane (natural gas), argon, helium, sulfur dioxide, etc.

To insure satisfactory operation, pressure should be not less than 10 psig at the flow meter inlet.

Minimum Flow Rates

The minimum flow rate which can be read is approximately 15% of full scale flow rate for all flow meters.

Installation Guidelines

Provide 10 pipe diameters of straight run in front of the flow meter. Install control valves or solenoid valves downstream of the flow meter if possible.

Services Not Recommended

Flow meter not recommended for the following kinds of service:

  • Resins, paints or monomers which can form solid deposits in the piping system

  • Super-solvents which attack most available elastomers

  • Sulfuric acid in any concentration

  • Foams which tend to have inconsistent densities

  • Toxic substances requiring hermetically sealed enclosures

  • Fluids with viscosity above 500 centipoise

  • Pumping systems using piston pumps which produce non-steady flow conditions

  • Gravity fed systems having less head than the pressure loss across the flow meter at normal operating conditions

FLO-GAGE
Dimensions
Nominal Series 7000 Series 8000
Size A A

Note: Dimensions are based on bronze meter.

Series 8000 Flo-Gage
RCM
110 Mason Circle Suit D    Concord, CA 94529-1238

PH: 925-687-8363    Toll Free: 888-flo-gage    Fax: 925-671-9636

e-mail: sales@flo-gage.com                         http://www.flo-gage.com